Reverse Engineering Information

From Simos Wiki
Jump to navigation Jump to search

Purpose of this section

Helpful links

Quick Reference

Memory address lookup

Registers a0, a1, a8, and a9 are used as offsets when the code needs to reference different memory locations. There's a table in the ECU that sets up those offsets at boot:

0000:808835CC                movh.a         a0, #0xD002
0000:808835D0                lea            a0, [a0]-0x8000
0000:808835D4                movh.a         a1, #0xA081
0000:808835D8                lea            a1, [a1]-0x8000
0000:808835DC                movh.a         a8, #0x8005
0000:808835E0                lea            a8, [a8]-0x7800
0000:808835E4                movh.a         a9, #0xD001
0000:808835E8                lea            a9, [a9]-0x4000

What that means, is that at any point in the code, these registers always have the following values:

a0:  0xD0018000
a1:  0xA0808000
a8:  0x80048800
a9:  0xD000C000

18.10:

a0:  0xD0018000
a1:  0x80828000
a8:  0x80028800
a9:  0xD000C000

A quick example of how this is implemented in code:

8019044a c9 00 de c9     ld.h       d0,[a0]-0x60e2

This takes the value of a0 (0xD0018000), subtracts 0x60e2 (=0xD0011F1E), and pulls the value of that memory address into d0. In the case of one common software version, that's:

      /begin MEASUREMENT tia_cha_up
         "Air Temperature upstream the Charger"
         SWORD
         _CNV_A_R_CHRG_LINEA_171_CM
         1
         100.
         -48.
         335.994140625
         DISPLAY_IDENTIFIER TIA_CHA_UP
         ECU_ADDRESS 0xd0011f1e
         FORMAT "%7.3"
         /begin IF_DATA ETK
            KP_BLOB
            0xd0011f1e
            INTERN
            2
            RASTER 30
         /end IF_DATA
      /end MEASUREMENT

Table address lookup